Panel, then the unit
A cold electric heater in Bouquet Junction is often the breaker. Holding while the tank stays cold points inside — element, thermostat or high-limit cut-out. Tripping straight back points at a shorted element or wiring.
Lukewarm water is its own signature: a failed upper circuit leaves the top unheated while the lower element warms slowly.
What gets tested
Resistance and continuity on each element, voltage at the thermostat, the high-limit switch, wiring and connections, breaker sizing. Each circuit separately, because symptoms overlap until measured.
Safety and scale
The breaker comes off before covers are opened, and the tank is drained below the element before it is touched. At 240 mg/L of calcium carbonate, elements also scale and fade in efficiency before they fail.