Skip to content

Repair

Gas water heater repair

Pilot lights that will not hold, thermocouple and flame sensor faults, dirty burners, gas valve and venting problems on Alhambra gas water heaters.

Where gas units fail

A gas storage heater has a small set of failure points, and they explain almost every no-hot-water call.

The pilot and thermocouple. The thermocouple is a small probe in the pilot flame that tells the gas valve the flame is lit. When it weakens, the valve shuts off seconds after you let the button go. The symptom is precise: the pilot lights, holds while you hold, and dies when you release.

The flame sensor and ignition. Standing-pilot units have a thermocouple; electronic-ignition units have a hot-surface igniter and a flame sensor. A sensor coated in oxide reports no flame when there is one, and the unit locks out with a code.

The burner. Dust, rust scale and spider webs in the burner tubes produce a lazy yellow flame, a rumble, or a smell of unburnt gas at start-up. Cleaning the burner and checking the orifices restores a blue flame and stops the sooting.

The gas valve and supply. A failing valve, a partially closed supply, or a regulator problem shows up as weak flame or no flow. Gas pressure is measured, not guessed.

Venting and combustion air. A flue that is blocked, disconnected, sagging or sharing a space with a dryer or a bathroom fan can backdraft exhaust into the room. This is the fault that matters most for safety and least for symptoms — carbon monoxide has no smell.

Why the flue gets checked every time

A heater that runs but vent drafts poorly is not fixed by a new thermocouple. On any gas repair, the draft, the flue connections, the clearances and the combustion air supply get looked at, because a unit that lights reliably and vents badly is a worse outcome than one that refuses to light.

When it is not the heater

The gas line, the shut-off valve and the meter belong to the supply side. If a second gas appliance is also failing, the problem is upstream of the heater and the utility is the first call. That gets established before parts are ordered.

Related reading

No hot water? What to check before you call runs the gas-side checks in order, from the sight glass to the point where guessing stops being useful.

Gas Water Heater Repair service areas

How coverage is decided

Get in touch

Pilot out, or no hot water on gas?

If you smell gas, leave the building and call the gas utility first. If there is no smell, the fault is usually in the pilot, sensor or gas valve.

Questions about this service

Why does my water heater pilot keep going out?

A worn thermocouple or flame sensor, a dirty pilot orifice, a downdraft from a blocked or badly routed vent, or a gas supply problem. The part is usually the cheap one, and the vent is the one that gets missed.

What should I do if I have no hot water?

On a gas unit, look at the pilot or the control's error light first. If the pilot is out and relights but will not stay, stop there and call rather than repeating the attempt.

Is a gas water heater safe to repair myself?

Changing a thermocouple is within reach for some homeowners, but gas valves, venting and combustion air are not. Venting faults in particular are not visible to the eye and are not something to guess at.

Why is the burner flame yellow instead of blue?

A yellow, lazy flame usually means incomplete combustion — dirt in the burner, wrong gas pressure, or a venting and air-supply problem. It needs looking at rather than living with.

Call(989) 601-2666