The flame is the first diagnostic
On a standing-pilot heater in Sleepy Valley, watching the pilot answers half the question. Lit and steady while the tank stays cold points at the burner or valve. Out, and the thermocouple or sensor is the likely cause. Lit only while the button is held and dead on release is the thermocouple's signature.
Electronic units report through a status light or code instead, naming ignition, flame-proving, venting or a limit — enough to know which system to test.
What gets checked
The pilot assembly, thermocouple or sensor, burner tubes and their air shutters, the gas valve and manifold pressure, and the flue, draft and combustion air. Venting is inspected on every gas call because a unit that lights reliably and vents badly is the dangerous one: carbon monoxide has no smell.
Repairs and limits
Thermocouples, sensors, burners and valves are serviceable. Gas piping, venting alterations and combustion air are not homeowner work, and a gas smell means leaving the building and calling the utility.