The sight glass tells you most of it
On a standing-pilot heater in The Oaks, the first check costs nothing: look at the pilot. Lit and the unit still cold points to the burner or the valve. Out, and the thermocouple or the flame sensor is the usual reason. Lit while you hold and dead on release is the signature of a thermocouple that can no longer prove flame.
On an electronic-ignition unit the control reports instead of the sight glass: a status light or code that says ignition, flame, venting or limit, which narrows the fault family immediately.
What a repair visit covers
The pilot assembly and orifice, the thermocouple or flame sensor, the burner tubes and their air shutters, the gas valve and supply pressure, the flue and its connections, the draft, and the combustion air available to the unit.
Why the flue is not optional
A gas heater that lights reliably and vents poorly is more dangerous than one that refuses to start. Carbon monoxide has no smell, so a blocked, sagging or disconnected flue is checked on every gas call rather than only when someone complains.
When it is not the heater
If another gas appliance in the property is also failing, the problem is upstream — the line, the valve or the meter — and the utility is the first call. That gets established before any part is ordered.