The drain tells you the interval
A tank in The Oaks holds water the city measures at 240 mg/L of calcium carbonate, with sample results from 160 to 290. That mineral comes out of solution when the water is heated and settles on the tank floor, where the burner then heats it before it heats any water.
The visible signs are a rumble or pop during recovery, hot water that runs out earlier each month, and a tank that takes longer to come back after a draw. The physical sign is what drains out: gritty, cloudy water means the interval should be shorter.
What the visit does
Isolates and drains the tank, flushes until the water clears, inspects the anode rod and replaces it where it is spent, tests the relief valve and confirms its discharge is clear and correctly piped, and checks the pan, drain, strapping and venting. On an on-demand unit the exchanger is descaled and the inlet filter cleaned. Power or gas goes back on only once the tank is full.
Why the anode matters more than the flush
Flushing deals with scale; the anode rod deals with corrosion. It is sacrificial — it corrodes so the steel does not — and once it is gone the shell starts to fail, usually from the base. That is why a tank can look healthy and be close to finished.
When to stop spending
A tank already leaking at the base is not a maintenance candidate. Neither is a heavily scaled unit with a corroded floor, where disturbing the sediment can start a leak the tank did not have.