Flushing is the job that pays
A storage tank in Pico fills with the same water the rest of Alhambra gets, and that water measures 240 mg/L as calcium carbonate with samples ranging from 160 to 290. The mineral settles on the tank floor; the burner then heats a layer of scale before it reaches the water. The results are a rumble during recovery, less hot water from the same tank, and a slower comeback after every draw.
Draining the tank breaks that layer up while it can still be moved. Left alone it hardens into a crust that insulates the water from the flame, and the unit runs longer to do less.
The part that decides the tank's life
Flushing addresses scale. The anode rod addresses corrosion: it is sacrificial, corroding so the steel does not. Once it is consumed, the shell starts to go, usually from the base — which is why a tank can look fine and be finished. Checking it during a flush is what makes the visit worth more than draining water.
The visit, in order
The tank is isolated and drained, the flush runs until the water clears, the anode is inspected, the relief valve is tested with its discharge confirmed clear, and the pan, drain, strapping and venting are reviewed. On a tankless unit the exchanger is descaled and the inlet filter checked. Power or gas is restored only once the tank is full.
When upkeep is the wrong spend
A tank already leaking at the base, or one whose shell has rusted through, is not a flushing candidate. On a heavily scaled tank with a corroded floor, disturbing the sediment can start a leak the unit was not going to have this year. Saying that plainly is part of the visit.