Two differences between flushing and protecting
Flushing handles mineral. At 240 mg/L of calcium carbonate, scale settles on the tank floor and the burner ends up heating it as well as water, so capacity and recovery fall away. Draining the tank breaks that layer up while it can still move.
The anode rod handles corrosion. It is sacrificial, corroding so the steel does not, and once it is spent the shell begins to fail from the base. That is why a tank can look healthy and be close to finished, and why the rod is checked at every maintenance visit rather than replaced on a schedule written on a website.
What the visit covers
Draining and flushing until clear, inspecting and replacing the anode where needed, testing the relief valve and confirming the discharge is clear and correctly piped, and reviewing the pan, drain, strapping and venting. Power or gas is restored only once the tank is full.
When not to spend
A tank leaking at the base is not a maintenance candidate, and a heavily scaled tank on a corroded floor can start leaking when the sediment is disturbed.