The tank that works but no longer delivers
A storage heater can pass every test and still disappoint: it heats, it shuts off, and the third shower is cold. That gap is where most tank calls start, and in Pico the local water makes one of the three causes far more likely than the others.
Sediment. At 240 mg/L of calcium carbonate, minerals settle on the tank floor and the burner heats scale before water. Capacity drops, recovery slows, the unit rumbles. Flushing recovers most of it on a tank not left too long.
A failed dip tube. Cold water enters through a tube that carries it to the bottom. When it breaks or drops off, cold water mixes at the top and leaves through the hot outlet — a full tank of hot water, a cold tap. An inexpensive part and a frequently missed diagnosis.
Element, thermostat or burner faults. These slow recovery rather than stopping it, and the fuel decides which side to check.
What ends a tank
A split shell, a base rusted through, or a tank patched twice. No part fixes those, and a tank leaking through steel keeps leaking until the water is off. Age matters less than condition: a flushed ten-year-old tank with a healthy anode rod outlasts a neglected six-year-old one.
The honest comparison
Repair cost against remaining life. A dip tube or thermostat on a sound tank is an easy yes. A burner assembly, a gas valve and a weeping base on a fifteen-year-old unit is a different conversation, and it belongs to whoever is paying.